Qatar YC/YCL Series Single-Phase Capacitor-Start Induction Motors
The YC/YCL series high-horsepower single-phase capacitor-start motors comply with IEC standards, offering high starting torque and reliable operation—perfect for applications such as water pumps, air compressors, agricultural irrigation systems, construction projects, and manufacturing industries.
Category:
Product Description
Introduction
The YC/YCL series high-horsepower single-phase capacitor-start motors comply with IEC standards, offering high starting torque and reliable operation—perfect for applications such as water pumps, air compressors, agricultural irrigation systems, construction projects, and manufacturing industries.
Motor characteristics
● Altitude not exceeding 1000m
● Ambient temperature: -15°C < 9 < 14°C
● S1 Continuous Operation Mode
● Class F, Class B insulation
● Protection rating: IP44
● B3 Installation Method
● IC0141 Air-cooling Method
Installation dimensions

| FRAME SIZE | MOUNTING DIMENSIONS (MM) | FRAME DIMENSIONS (MM) | |||||||||||||||||||
| A | B | C | D | E | F | G | H | K | M | N | P | R | S | T | AB | AC | AD | AE | HD | L | |
| 80 | 125 | 100 | 50 | 19 | 40 | 6 | 15.5 | 80 | 10 | 165 | 130 | 200 | 0 | 12 | 3.5 | 160 | 165 | 120 | 110 | 200 | 310 |
| 90S | 140 | 100 | 56 | 24 | 50 | 8 | 20 | 90 | 10 | 165 | 130 | 200 | 0 | 12 | 3.5 | 180 | 185 | 140 | 120 | 240 | 365 |
| 90L | 140 | 125 | 56 | 24 | 50 | 8 | 20 | 90 | 10 | 165 | 130 | 200 | 0 | 12 | 3.5 | 180 | 185 | 140 | 120 | 240 | 385 |
| 100L | 160 | 140 | 63 | 28 | 60 | 8 | 24 | 100 | 12 | 215 | 180 | 250 | 0 | 15 | 4.0 | 205 | 220 | 145 | 130 | 260 | 415 |
| 112M | 190 | 140 | 70 | 28 | 60 | 8 | 24 | 112 | 12 | 215 | 180 | 250 | 0 | 15 | 4.0 | 245 | 250 | 160 | 140 | 200 | 440 |
| 132S | 216 | 140 | 89 | 38 | 80 | 10 | 33 | 132 | 12 | 265 | 230 | 300 | 0 | 15 | 4.0 | 280 | 262 | 210 | 150 | 350 | 470 |
Technical Specifications
| Model | Rated Output |
Full load Voltage V |
Rated Current A |
Rated Speed RPM |
Efficiency n % |
Power Factor COSΦ |
Ts/Tn Times |
Tmax/Tn Times |
Ist/ln Times |
||
| kW | HP | ||||||||||
| YC80A-2 | 0.37 | 0.5 | 220 | 3.5 | 2880 | 65 | 0.73 | 2.8 | 1.8 | 6.5 | |
| YC80B-2 | 0.55 | 0.75 | 220 | 5.1 | 2880 | 68 | 0.73 | 2.8 | 1.8 | 6.5 | |
| YC80C-2 | 0.75 | 1 | 220 | 6.4 | 2880 | 70 | 0.75 | 2.4 | 1.8 | 6.5 | |
| YC90S-2 | 1.1 | 1.5 | 220 | 8.7 | 2880 | 72 | 0.77 | 2.4 | 1.8 | 7.0 | |
| YC90L-2 | 1.5 | 2 | 220 | 11.6 | 2900 | 74 | 0.78 | 2.4 | 1.8 | 7.0 | |
| YC100-2 | 2.2 | 3 | 220 | 16.4 | 2900 | 75 | 0.79 | 2.1 | 1.8 | 7.0 | |
| YC80A-4 | 0.25 | 0.33 | 220 | 3.3 | 1450 | 58 | 0.60 | 2.8 | 1.8 | 6.0 | |
| YC80B-4 | 0.37 | 0.5 | 220 | 4.3 | 1450 | 62 | 0.62 | 2.8 | 1.8 | 6.0 | |
| YC80C-4 | 0.55 | 0.75 | 220 | 5.7 | 1450 | 66 | 0.65 | 2.8 | 1.8 | 6.0 | |
| YC90S-4 | 0.75 | 1 | 220 | 7.4 | 1450 | 68 | 0.66 | 2.4 | 1.8 | 6.5 | |
| YC90L-4 | 1.1 | 1.5 | 220 | 10 | 1450 | 71 | 0.68 | 2.4 | 1.8 | 6.5 | |
| YC100L-4 | 1.5 | 2 | 220 | 12.9 | 1450 | 73 | 0.70 | 2.4 | 1.8 | 6.5 | |
| YC112M-4 | 2.2 | 3 | 220 | 18.5 | 1450 | 74 | 0.72 | 2.2 | 1.8 | 6.5 | |
| YC132SA-4 | 3 | 4 | 220 | 24.1 | 1450 | 75 | 0.73 | 2.1 | 1.8 | 6.5 | |
| YC132SB-4 | 3.7 | 5 | 220 | 28.7 | 1450 | 76 | 0.74 | 2.1 | 1.8 | 6.5 | |
| YCL90S-2 | 1.1 | 1.5 | 220 | 6.9 | 2880 | 73.2 | 0.95 | 2.8 | 1.8 | 6.0 | |
| YCL90L-2 | 1.5 | 2 | 220 | 8.5 | 2900 | 76.0 | 0.97 | 2.8 | 1.8 | 7.0 | |
| YCL100L-2 | 2.2 | 3 | 220 | 12.6 | 2900 | 78.8 | 0.96 | 3.0 | 1.8 | 6.5 | |
| YCL90S-4 | 0.75 | 1 | 220 | 5.3 | 1450 | 73.3 | 0.93 | 2.8 | 1.8 | 6.5 | |
| YCL90L-4 | 1.1 | 1.5 | 220 | 7.5 | 1450 | 75 | 0.90 | 2.5 | 1.8 | 6.0 | |
| YCL100L-4 | 1.5 | 2 | 220 | 8.9 | 1450 | 79.4 | 0.92 | 2.8 | 1.8 | 7.0 | |
| YCL112M-4 | 2.2 | 3 | 220 | 12 | 1450 | 81.6 | 0.90 | 2.3 | 1.8 | 6.5 | |